Inverters
WIT Series Three-Phase Hybrid Inverter 29.9–50 kW
Three-phase hybrid inverter from 29.9 kW to 50 kW with 4 MPPTs, three battery inputs (200–900 V), backup output and IP66 protection.
Series range
- Max. efficiency
- 98.1%
- Dimensions (W×H×D)
- 920 × 585 × 320 mm
- Weight
- 90 kg
Key features
- Multiple MPPTs and battery inputs
- Supports diesel generator input and smart load function
- Supports UPS function and black start
- Supports multi-system parallel operation in off-grid mode
- Intelligent air cooling, no derating at 50 °C ambient temperature
- 100% three-phase unbalanced output and 150% off-grid overload capacity
- Strong grid adaptability, supports weak grids with SCR <1.2
Specifications
Scroll sideways to see all models.
| Model | WIT 29.9K-XHU | WIT 30K-XHU | WIT 36K-XHU | WIT 40K-XHU | WIT 50K-XHU |
|---|---|---|---|---|---|
| DC Input (PV) | |||||
| Max. recommended PV power (module STC) | 59.8 kW | 60 kW | 72 kW | 80 kW | 100 kW |
| Start voltage | 195 V | ||||
| Max. DC voltage | 1100 V | ||||
| Nominal voltage | 620 V | ||||
| Max. open-circuit PV voltage | 1000 V | ||||
| Operating voltage range | 180–1000 V | ||||
| Full-load DC voltage range | 375–850 V | 375–850 V | 450–850 V | 500–850 V | 620–850 V |
| Max. input current per MPPT | 40 A | ||||
| Max. short-circuit current per MPPT | 50 A | ||||
| Strings per MPPT | 2 | ||||
| Number of MPPT | 4 | ||||
| Battery | |||||
| Battery voltage range | 200–900 V | ||||
| Full-load battery voltage range | 200–800 V | 200–800 V | 225–800 V | 250–800 V | 310–800 V |
| Recommended battery voltage | 512 V | ||||
| Number of battery inputs | 3 | ||||
| Max. charge/discharge current | 55 A × 3 | ||||
| BMS communication | RS485 / CAN | ||||
| AC Input/Output (Grid) | |||||
| AC input/output nominal power | 59.8 kW / 29.9 kW | 60 kW / 30 kW | 72 kW / 36 kW | 80 kW / 40 kW | 100 kW / 50 kW |
| Max. AC input/output apparent power | 59.8 kVA / 29.9 kVA | 66 kVA / 33 kVA | 79.2 kVA / 39.6 kVA | 88 kVA / 44 kVA | 110 kVA / 55 kVA |
| Max. input/output current | 90.6 A / 45.3 A | 100 A / 50 A | 120 A / 60 A | 133.3 A / 66.7 A | 166.7 A / 83.3 A |
| Max. input current (generator / AC coupling) | 90.6 A / 45.3 A | 100 A / 45.5 A | 120 A / 54.5 A | 133.3 A / 60.7 A | 166.7 A / 75.7 A |
| Max. continuous AC passthrough current | 200 A | ||||
| Nominal AC voltage / range | 380/400 V, -15% to +10% | ||||
| AC grid frequency / range | 50/60 Hz, 45–55 Hz / 55–65 Hz | ||||
| Power factor (@nominal power) | >0.99 | ||||
| Adjustable power factor | -1 … +1 | ||||
| THDi | <3% | ||||
| Grid connection | 3P3W+PE / 3P4W+PE | ||||
| Backup Output | |||||
| AC nominal output power | 29.9 kW | 30 kW | 36 kW | 40 kW | 50 kW |
| Max. AC apparent power | 29.9 kVA | 45 kVA | 54 kVA | 60 kVA | 75 kVA |
| Nominal AC voltage | 220/230 V (L-N), 380/400 V (L-L) | ||||
| Nominal frequency | 50/60 Hz | ||||
| Max. output current | 68.0 A | 68.2 A | 81.8 A | 91 A | 113.6 A |
| Overload capacity | 1.5 × rated power for 10 s | ||||
| THDv | <3% (@linear full load) | ||||
| Switch time | ≤10 ms | ||||
| Efficiency | |||||
| Max. efficiency | 98.1% | ||||
Common specifications
| Protections | DC reverse polarity, battery reverse, insulation resistance monitoring, AC/DC surge protection Type II, AC short-circuit, ground fault monitoring, grid monitoring, string monitoring, anti-islanding, residual-current monitoring |
|---|---|
| Dimensions (W×H×D) | 920 × 585 × 320 mm |
| Weight | 90 kg |
| Operating temperature | -30 to 60 °C (derating >50 °C) |
| Noise emission | ≤55 dB |
| Max. operating altitude | 4000 m |
| Topology | Transformerless |
| Cooling | Smart air cooling |
| Protection degree | IP66 |
| Relative humidity | 0–95% |
| Display | OLED + LED / app |
| Communication | RS485/USB/CAN; Wi-Fi/LAN: optional |
| Warranty (5/10 years) | Yes / optional |
| Standards (as listed) | CE/CB, RoHS, IEC 62109-1, IEC 62109-2, IEC 62477-1, EN 62920, IEC 61000-6-4, IEC 61000-6-2, IEC 61000-3-12, IEC 61000-3-11, EN 55011, IEC 62116, IEC 61727, IEC 61683, IEC 60068-2-1, NRS 097-2-1 |
| Note | The AC voltage range may vary depending on the specific country grid standard. All specifications are subject to change without notice. |
Specifications follow the manufacturer datasheet and may change without notice. Please confirm the exact model before ordering.
Certifications
Listed in the manufacturer datasheet
CE/CB, RoHS, IEC 62109-1, IEC 62109-2, IEC 62477-1, EN 62920, IEC 61000-6-4, IEC 61000-6-2, IEC 61000-3-12, IEC 61000-3-11, EN 55011, IEC 62116, IEC 61727, IEC 61683, IEC 60068-2-1, NRS 097-2-1
A datasheet listing is not a certificate. Ask us for the certificate that covers your exact model and market. Request a certificate
Talk to our sales team about sizing, lead time and certificates for your market.
Request a Quote